SYA12K16IXR Symmetra Features & Benefits
Key Features
Save time with easy and convenient remote accessibility.
Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Modular, Scalable, Redundant Architecture future proof initial investment, improves equipment availability, and simplifies maintenance.
Symmetra LX’s redundant N+1 architecture enables the unit to withstand a failures of an intelligence module, battery or power module. Modules are easily replaceable in the field. Customers can add additional power modules or batteries after initial equipment purchase to accommodate loads of up to 16 kVA.
Peace of mind that comes with complete equipment compatibility and reliability of a market leader .
Safety agency tested and approved means that you can deploy Symmetra with confidence that they meet or exceed the industry’s most rigorous standards.
Avoids costly power problems by keeping your IT equipment and data protected and available .
Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Low operating and maintenance costs with proven reliability and intelligent battery management .
Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Cold-start capable
Provides temporary battery power when the utility power is out.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Resettable circuit breakers
Enables a quick recovery from overload events.
Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Key Benefits
Availability
Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Modular design
Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.
Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
Configurable for N+1 internal redundancy
Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Scalability
Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Scalable runtime
Allows additional run time to be quickly added as needed.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Programmable frequency
Ensures compatibility with different input frequencies.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
Manageability
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
Intelligent Card Slot
Customize UPS capabilities with management cards.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serviceability
User-replaceable intelligence modules
Enables simple upgrades and replacements of the Intelligence Modules.
User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS conditions.
Technical Specifications
ain Input Voltage | 230 V 400 V 3 phases |
---|---|
Other Input Voltage | 220 V 240 V 380 V 415 V |
Main Output Voltage | 230 V |
Other Output Voltage | 220 V 240 V |
rated power in W | 8400 W |
rated power in VA | 12000 VA |
output connector type | Hard wire 3-wire (H N + E) 1 |
battery type | Lead-acid battery |
provided equipment | CD with software Documentation CD User manual Web/SNMP management card |
product web sub-family | 4kVA power increments |
---|---|
Number of power module free slots | 2 |
Number of power module filled slots | 3 |
redundant | Yes |
colour | Black Silver |
---|---|
height | 151.6 cm |
width | 48.3 cm |
depth | 72.6 cm |
net weight | 488.64 kg |
mounting location | Front |
mounting preference | No preference |
mounting mode | Not rack-mountable |
two post mountable | 0 |
USB compatible | No |
network frequency | 45...65 Hz auto-sensing |
---|---|
number of input connectors | 1 hard wire 3-wire (1P + N + E) 1 hard wire 5-wire (3P + N + E) |
input voltage limits | 155...276 V 1:1 290...480 V 3:1 |
input harmonic distortion | Less than 7 % for full load |
Input Power Factor at Full Load | 0.98 |
Maximum configurable power in W | 11200 W |
---|---|
harmonic distortion | Less than 5 % at full load |
output frequency | 47...63 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
crest factor | Up to 5 : 1 |
UPS type | Double conversion online |
Wave type | Sine wave |
bypass type | Internal bypass (automatic and manual) |
maximum output current | 55 A |
Maximum configurable power in VA | 16000 VA |
product certifications | C-Tick CE GOST VDE |
---|---|
standards | EN 50091-1 EN 50091-2 EN 55022 class A EN 55024 EN 60950 IEC 60950 |
ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
operating altitude | 0...10000 ft |
ambient air temperature for storage | -15…45 °C |
storage Relative Humidity | 0…95 % |
storage altitude | 0.00…4572.00 m |
acoustic level | 62 dBA |
heat dissipation | 3707 Btu/h |
number of battery filled slots | 9 |
---|---|
number of battery free slots | 4 |
Battery recharge time | 7.5 h |
additional information | Configurable for 220 : 230 or 240 nominal output voltage |
battery charger power | 1035 W rated |
Battery power in VAH | 7776 VAh runtime |
battery life | 3…5 year(s) |
battery option | SYBT5 2 9504 VAh SYBT5 4 11232 VAh SYAXR9B9I 1 15552 VAh SYAXR9B9I 2 23328 VAh SYAXR9B9I 3 31104 VAh SYAXR9B9I 4 38880 VAh SYAXR9B9I 5 46656 VAh SYAXR9B9I 6 54432 VAh |
extended runtime | 1 |
free slots | 1 |
---|---|
preinstalled device | Network management card 2 with environmental monitoring |
control panel | Multifunction LCD status and control console |
alarm | Audible and visible alarms prioritized by severity |
Emergency power off | Yes |
Package 1 Weight | 520.46 kg |
---|---|
Package 1 Height | 188 cm |
Package 1 width | 59.9 cm |
Package 1 Length | 99.7 cm |
Number of Units in Package 3 | 1 |
Warranty | 2 years repair or replace |
---|